![Harman AMX JPK-1300 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/harman/amx-jpk-1300/amx-jpk-1300_hardware-reference-manual_3959861050.webp)
Control Commands (Direct Control)
Reference Manual - JPK-1300
50
No. Command
Function Description
Example
22
set relay normal
state:<relay_state>
Variables:
<relay_state>=
{
open
closed
}
Default Value:
open
Set relay normal state
Command:
set relay normal state:closed
Return
:
set relay 1 and relay 2 normal state closed
23
get relay momentary time
Variables:
<time>= 0 ~ 120 s
Default Value:
0 s
Get relay momentary time
Command:
get relay momentary time
Return
:
get relay momentary time 10s
24
set relay momentary
time:<time>
Variables:
<time>= 0 ~ 120 s
Default Value:
0 s
Set relay momentary time
Command:
set relay momentary time:20
Return
:
set relay momentary time 20s
25
get relay disp port
Get relay port for screen up and
down control
Command:
get relay disp port
Return
:
get relay 1 for screen down, relay 2 for screen up
26
set relay disp
port:<screen_up_down>
Variables:
<screen_up_down> =
{
12,
(screen up
controlled by relay1, screen
down cotnrolled by relay2)
21,
(screen up controlled
by relay2, screen down
cotnrolled by relay1)
}
Default Value:
21
Set relay port for screen up and
down control
Command:
set relay disp port:12
Return
:
set relay 1 for screen up, relay 2 for screen down
27
get relay disp off delay
Variables:
<time>= 0 ~ 300 s
Default Value:
30 s
Get relay control display off
delay time
Command:
get relay disp off delay
Return
:
get relay control display off delay 30s