Installation and Connection
Cable Requirements
1.
CONTROL port connection distance is up to 164ft/50m via a Shielded Cat 6/6A/7 cable. The CONTROL cable must be pre- run from the
Wall-plate Transmitter backbox to the Keypad backbox.
2.
AV LINK port connection distance is up to 230ft/70m for 1080P video or 131ft/40m for 4K video via a Shielded Cat 6/6A/7 cable.
The AV LINK cable must be pre-run from the Receiver installation location to the Wall-plate Transmitter backbox.
Install Jetpack Receiver
1.
Position and install the mounting brackets of JPK-1300 RX with the 4 mounting screws provided, as shown below.
JPK-1300 RX
2.
Mount and secure the JPK-1300 to a surface or a suitable location using appropriate mounting screws.
Connect Jetpack Receiver
1.
Connect the pre-run AV LINK cable to the AV LINK port on the JPK-1300 RX.
2.
Connect the power adapter provided to the JPK-1300 RX.
3.
Connect HDMI OUT
Connect an HDMI display device (such as a projector) to the HDMI OUT port of the JPK-1300 RX.
4.
Connect USB DEVICE
Connect an USB device (such as a Smart Board) to the USB DEVICE port of the JPK-1300 RX.
5.
Connect MICROPHONE or OTHER ROOM AUDIO SOURCE
Connect an audio source (such as a microphone) to the MIC/LINE IN port of the JPK-1300 RX. (Make sure the MIC/LINE switch is
turned to MIC when connecting a microphone to the MIC/LINE IN port.).
6.
Connect AUDIO OUT
Connect the AUDIO OUT port to an amplifier or powered speakers and/or connect the AMP OUT port to 4/8 Ohm speakers
using appropriate speaker cables.
7.
Connections for additional control options:
•
LAN control (Web UI/PC tool/Telnet/SSH): Connect the JPK-1300 RX to the same network of the PC or control system
via the LAN.
•
RS-232/IR/RELAY control: Connect the RS-232 or IR OUT port of the JPK-1300 RX to the display device such as a projector via an
RS-232 cable or the IR emitter cable provided, and connect the RELAY port (1-2) to the electric lifting projection screen.
•
Remote mute control: Connect the REMOTE MUTE port of the JPK-1300 RX to the contact closure of the fire alarm
system.
Note:
Please refer to the Instruction manual for the configuration of RS-232/IR/RELAY control and the REMOTE MUTE.
Connect Jetpack Devices
1.
Connect one end of the pre-run CONTROL cable to the CONTROL port on the JPK-1300 Wall-plate TX and the other end to the
CONTROL port on the JPK-1300 keypad.
2.