HARDT
Responsive, Reliable Solutions
CUS-009-0028-11
Page 19 of 21
5.4.3
Making Gas Connections
1. Connect the restraining cable to the anchor hole located
at the rear of the rotisserie (see Figure 5-6) and to the
wall using the wall-mount bracket. The restraining cable
and the wall mount bracket are supplied with the quick-
disconnect kit (the kit must be ordered along with the
rotisserie). The wall mount bracket must be installed by
a qualified contractor.
2. The gas connection is located behind the right rear
corner of the rotisserie. See Figure 5-6.
3. Apply an approved thread sealant to the threaded pipe
end on the gas pipe extending from the rear of the
rotisserie.
4. Screw the Quick-Disconnect fitting (pipe adapter shown
in Figure 5-5) onto the threaded connection.
5. Attach the flexible gas supply hose to the facility gas
supply line and connect the gas to the rotisserie by
sliding the Quick-Disconnect hose fitting onto the pipe
adapter.
6. Open the main gas valve from the facility gas supply
line(s).
7. Check all hoses, fittings and connections for leaks prior
to operating the rotisserie.
Figure 5-6
FAILURE TO CHECK FOR LEAKS MAY RESULT IN INJURY OR DEATH.
GAS CONNECTION,
THREADED PIPE
END
RESTRAINING CABLE
ANCHOR LOCATION