5 - Operation
Pressure filters
Pressure filters will catch any remaining impurities and prevent nozzles
clogging. To avoid blockage of those filters it is very important to check
them regularly and clean them after each spray job to avoid chemical
residues to deposit and block
WARNING! Wear appropriate personal protection when
checking pressure filteres. As a minimum gloves and face shield.
Agitation
The dual-nozzle agitation system injects the chemical product at high
pressure from the pump inside the tank creating a turbulence that
mixes the product with the water to a uniform liquid.
The standard agitation has 2 mm ventury nozzles. The ventury nozzle
(B) allows an effecient agitation of the main tank content.
Clean water tank
The clean water tank is located at the top and integrated in the main
tank design. It is used for washing hands, gloves and cleaning clogged
nozzles, etc.
Unscrew the cap (A) to fill the tank. Open the tap (B) for clean water.
WARNING! Although this tank is completely separate from the
main tank and should only be filled with clean water, the water
is NOT suitable for drinking!
Powder mixer
This is mixer will flush and dissolve powder chemicals through the tank
strainer, eliminate lumpy spray liquid and improve mixing.
ATTENTION! After use, the powder mixer should be switched off,
as it uses a lot of flow.
A
B
B
A