99
6 - Maintenance
Adjusting the 3-way valve
The 3-way valve can be adjusted if it is too tight or too loose (liquid
loss). It is correctly adjusted when the valve handle can be turned
using one hand only.
To ease operation clean the mating faces between ball (B) and the seat
(A) of the valve.
Grease the valve every time you dismantle it for cleaning. This will
extend the service life of ball and seat.
Replacing the driveshaft protector guard
1. Remove the screw (A), cap (B) and grease nipple (C): Twist the
cover a quarter of a turn and pull it back.
2. Remove the synthetic bearings and the protection guard.
3. R emove the inner bush from the protection guard.
4. Re-assemble in the reverse order, using new parts if necessary.
Remember to assemble the chains again.
5. Grease the bearings.
ATTENTION! Only use original HARDI parts to repair the
driveshaft.
Replacing the driveshaft crossheads
1. Remove the protection guard as described previously.
2. Remove the Seger rings.
3. Press the cross journals to one side (use a hammer and mandrel
if necessary).
4. Remove the cross journal bearings and then remove the cross
journal.
5. Remove the bearings from the new cross journal carefully and
then install it. Before fitting the bearings again, check that the
unit is assembled correctly. Protect the new bearings from dirt
and dust.
A
C
B
A B
Содержание ZENIT 400