38
4 - Starting up
Hydraulic connections
General information
Make sure that the couplings are clean before fitting them!
After pressing the brake pedal and when the system has filled with oil, check the level of hydraulic oil in the tractor and
refill if required.
DANGER! Testing the hydraulic system should be done with care. Air may have entered the system and cause
sudden movements.
DANGER! Oil leakage: Do not use your hands under any circumstances to locate a leakage in any point in the
hydraulic system. Due to the system’s high pressure, the oil could penetrate the skin.
Tractor requirements
Hydraulic pressure of 180 Bat and a flow of 20 l/Min or 5 gal / min.
Below you’ll find a table where the boom requirements are listed as 2D = 2 double acting hydraulic outlets 3D = double
acting outlets etc.
Converted to 1 Double acting outlet.
All booms offer optionally a Small Joystick S3 or S5 to cover up to 5 double acting functions into just 1 double acting
outlet.
Larger booms and sprayer with Combus circuit, are offered with V hydraulics, known as well as DAH – Direct activated
Hydraulic.
Boom
Hydraulic rams
Operated by
Optional or default
Liner
Fix
N
Start
N
Start Fix
N
Atlas
Start H0
N
Start H2
2D
S3 or controlbox
Start H3
3D
S3 or controlbox
Agile Fix H3
3D
S3 or controlbox
Solid FIX H3
3D
S3 or controlbox
Solid Convert H3
3D
S3 or controlbox
Solid GV Fix H5
5D
S5 or controlbox
Solid GV Convert H5
5D
S5 or controlbox
Boxer
Start
2D or 3D or 5D
S3 or S5 or controlbox
Agile
2D or 3D or 5D
S3 or S5 or controlbox
Solid
3D or 5D
S3 or S5 or controlbox
Cronos
Solid H3
3D
S3 or combus
Solid GV H5
5D
S5 or combus
Rider H3
3D
S3 or combus
Rider HV H5
5D
S5 or combus
Varia Convert H5
5D
S5 or combus
Varia GV Convert H7
7D
Combus