4 - Sprayer setup
63
Power supply
Power requirement is 12V DC. Always note polarity! For proper function
of the electric equipment, the wires must have the following
recommended cross sectional areas and correct fuses to ensure a
sufficient power supply. The delivered power connectors follows the
standard of most newer tractors. If you have a tractor with another
power connector, it is necessary to disassemble the connector and fit it
to the actual tractor connector.
The number and the type of connectors may vary on the specific
sprayer, depending on its equipment.
CIGAR CONNECTOR
Spray control unit requires:
Wire 2.5 mm
2
, Fuse 10 Amp
Hydraulic control unit requires:
Wire 4.0 mm
2
, Fuse 16 Amp
7 POLE TRAFFIC LIGHT CONNECTOR
JOBCOM CONNECTOR
The unit requires:
Wire 6.0 mm
2
, Fuse 25 Amp
WORKING LIGHT CONNECTOR
The unit requires:
Wire 10.0 mm
2
, Fuse 30 Amp
ISO POWER CONNECTOR
13 POLE POWER CONNECTOR