66
-
68
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
Spider
EN
Voercomputer—Feeding computer—Fütterungscomputer—ordinateur d
’
alimentation
Index
13.5 Annex control motors
Engine
Possible
Feedback
Notes
Solidstate 5
Yes –
Standard
Yes
Sol
Rather not
No
Old motor
-
Preferably replace with a Solidstate 5. Soli
can be used. Connect brown, white and green, and add a 2k2
resistor to green and grey.
Intelligent
motor
Yes
No
More expensive motor and no feedback, do not recommend.
RIM puls
Yes
No
More expensive motor. Do not connect feedback.
RIM time
Yes
No
More expensive motor. Do not connect feedback.
Grey motor
Yes
Yes
Downside to sliders and less stronger because it is 40 RPM. Pref-
erably replace with a Solidstate 5.
Black Nedap
motor
Yes
Yes
Huge disadvantages are the sliders and the fact that this motor
draws much more current. Preferably replace it with a Solidstate
5. When connecting a Nedap motor, connect red to the green
connection.
AC motoren
No
No
Using a relay it would be possible but without feedback. Not test-
ed, so no. Not anti
-
spill.
DC time
-
controlled
motors
Yes
No
Not what we would advise, but it is possible.
Not anti
-
spill.