GB
48
IMPORTANT:
• When starting the machine there may be a temporary voltage drop in the mains supply, which could
affect other equipment� Such interference does not normally occur if the impedance in the mains
supply Zmax is less than 0�335 ohm� You may need to contact your electricity supplier for more
information�
• Check the power cord� A damaged power cord must be replaced by an authorised service centre, or
qualified person, to ensure safe use�
• Do not use contaminated water� Fit an extra filter if there is a risk of getting sand in the incoming
water (e�g� from your own well)� Wear a suitable filter�
MAINS CONNECTION
• The following items should be taken into consideration during the electrical installation�
–
Electrical installations must be carried out by an authorised electrician� Electrical installations
must comply with IEC-364�
–
The machine must be connected to the mains supply with a residual current device with a
maximum tripping current of 30 mA�
SAFETY DEVICES
• The machine is equipped with an overpressure valve� The spray gun has a trigger lock�
• The motor is equipped with overheating protection� The machine starts again after a few minutes,
when it has cooled�
TECHNICAL DATA
Rated voltage:
220–240 VAC, 50 Hz
Output:
1800 W
Safety class:
II
Protection rating:
IPX5
Rated pressure:
100 bar
Max pressure:
140 bar
Rated flow:
6�67 l/min
Max flow:
7�2 l/min
Operating temperature:
0–40°C
Max inlet pressure:
7 bar
Weight:
12�5 kg
Sound pressure level, L
pA
77 dB(A), K= 3 dB
Measured sound power level, L
wA
90 dB(A), K= 3 dB
Guaranteed sound power level, L
wA
92 dB(A)
Vibration level:
does not exceed 2�5 m/s²