installation
CONVERSION KIT #743-969 FROM NG TO LP
H35
919-519a
04.14.15
CONVERSION KIT #743-969 FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG
Conversion Kit
LP Conversion Kit Contains:
Qty. Part #
Description
1 904-529
5/32" Allen Key
1
904-390
Burner Orifice #52
1 918-590
Label "Converted to
LPG"
1 908-528
Red "LPG" label
1
910-101
LP Injector (Pilot Orifice)
1 911-011
Stepper Motor
1
919-519
Instruction Sheet
Remove the 2 screws, push Burner
Assembly to the left and lift out.
Burner Orifice
Installation of LPG Conversion Kit:
1)
Shut off the gas and electrical sup-
ply.
2)
Lift off the Cast Top and remove the
cast. Also, remove the glassdoor.
3)
Remove the logs, embers, and brick
panels (if used).
4)
Remove the 2 screws holding the
Burner Assembly to the firebox base.
Push the Burner Assembly to the left
and lift out.
5)
Pull off the pilot cap to expose the
pilot orifice.
6)
Unscrew the pilot orifice with the allen key
and replace with the LP pilot orifice in the
kit and replace pilot cap.
7)
Remove burner orifice with a 1/2" wrench
and discard. Use another wrench to hold
on to the elbow behind the orifice.
8) Reinstall new burner orifice LP stamped
#52
and
tighten
.
9)
Open the front panel and remove the cover
plate by removing two screws.
10)
Disconnect the NG stepper motor wires from
the receiver in location show below.
Remove NG Stepper motor and replace
with LP Stepper motor
12)
Connect the LP stepper motor to the
receiver (same port as NG stepper
removed from in Step 10).
13)
Reinstall the cover plate and the front
panel.
14)
Attach the label “This unit has been
converted to LPG” near or on top of the
serial # decal.
15)
Replace yellow “NG” label with red “LPG”
label.
16)
Reverse steps 4 through 1
17)
Check for gas leaks.
18)
Check inlet and outlet pressures.
19)
Check operation of flame control.
Installer Notice:
These instructions must be left
with the appliance.
Take the valve cover plate out
11. Remove NG stepper motor by removing 2
screws in locations shown below. Replace
with LP stepper motor, secure in place
with 2 screws.