![HAMPTON BAY H35-10 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/hampton-bay/h35-10/h35-10_owners-and-installation-manual_3544925020.webp)
20
|
Hampton® H35-10 Direct Vent Freestanding Gas Stove
|
20
installation
VENTING ARRANGEMENTS
HORIZONTAL TERMINATIONS USING RIGID PIPE
Snorkel Termination
Riser Vent Termination
The two diagrams show all allowable com
-
binations of straight horizontal termination
using Rigid Pipe. Restrictor position "A".
Only a snorkel or FPI Riser vent may be
used as shown. No other termination cap
is permitted.
Venting Arrangements -Straight Horizontal Termination
The diagrams show all allowable combina
-
tions of straight horizontal termination using
Rigid Pipe. Restrictor position "A".
Only a snorkel or FPI Riser vent may be used
as shown in the noted diagrams. No other
termination cap is permitted.
Dangerous operating conditions will occur
if these instructions are not adhered to.
*If this is an outside corner, the minimum dis
-
tance between the vent and the outside corner
is 6” (15cm). See “F” on the diagram in the
"Exterior Vent Terminal Locations" section.
Snorkel Termination
Riser Vent Termination