Hampton® H35-10 Direct Vent Freestanding Gas Stove

 | 

30

installation

Termination

Cap

Top Adaptor

Existing

Metal

Chimney

System

4" Aluminum

Flex Pipe

Retro

Connector

Any Simpson

Dura-Vent

black direct vent

pipe plus an

adjustable length

to make a

proper connection.

CONVERTING 
CLASS-A METAL 
CHIMNEY OR 
MASONRY CHIMNEY 
TO DIRECT  
VENT SYSTEM

There are two different types of direct vent conver-

sion systems listed below. Follow the appropriate 

directions for your installation.

A)  Through an existing factory built metal chimney 

going through the ceiling: A typical conversion 

of this type is shown in diagram 1. The concept 

of direct vent conversion is to connect an adap-

tor to an Underwriters Laboratories (UL) listed 

4 inch diameter aluminum flex pipe which is 

then passed down through the center of the 

existing  metal  chimney  system.  Three  sizes 

of Top Adaptors are available from Simpson 

Dura-Vent. The Retro Connector is attached 

to the bottom of the flex pipe. The Top Adaptor 

and the Retro Connector are attached to the 

existing chimney with sheet metal screws. The 

appliance is then connected to the chimney 

with appropriate black direct vent pipe and an 

adjustable length  section.

B)  Through  the  wall  of  an  existing  masonry 

chimney: A  typical  conversion  of  an  existing 

masonry chimney is shown in Diagram 6. A Top 

Adaptor and Flashing are used at the top of the 

masonry chimney. The 4 inch aluminum liner is 

connected to the adaptor and is passed down 

the chimney and out through the  masonry wall 

and attached to the Retro Connector . The Retro 

Connector is attached to the masonry wall and 

then connected to the direct vent pipe leading 

to the appliance.

Prior to installation and connection of the vent 

system to a factory-built or masonry chimney, 

the chimney must be inspected and thoroughly 

cleaned by a qualified service person, such as 

a certified chimney sweep or home inspection 

service.

 

The direct vent system must not be connected 

to a damaged factory-built or masonry chimney.

For factory built, zero clearance, and masonry 

chimneys cleanout doors and caps or plugs for 

cleanout tee fittings and ash dumps shall be 

secured in place and sealed before installing a 

Direct Vent system within the chimney.

If  the  appliance  shuts  off  during  operation, 

contact a qualified service person to determine 

if  a  negative  pressure  and/or  leaky  chimney 

condition exists. Do not operate the appliance 

until the problem is corrected.

Converting a Factory Built Metal 
Chimney

1)

  Remove the existing chimney cap.

2)

  Measure the distance from the top end of the 

chimney to the bottom of the ceiling support 

box, add 3" (76mm) to this measurement, and 

cut a section of the 4" (102mm) flex pipe to that 

length (the flex should already be extended to 

its nominal length).

3)

  Connect the end of the flex pipe section to the 

underside  of  the  Top Adaptor  using  3  sheet 

metal screws (refer to Diagram 2).

4)

  Pass the flex pipe down through the center of 

the chimney system, and center the adaptor 

on the top of the chimney pipe. Drill four 1/8" 

diameter holes through the adaptor and into 

the chimney top. Insure that   you are in fact, 

drilling into the metal on  the chimney. Twist-lock 

the Termination Cap onto the Adaptor (refer to 

Diagrams 3 and 4).

Diagram 1

Diagram 2

5)

  Pull  the  flex  pipe  down  through  the  ceiling 

support box, until it protrudes approximately 

3" (76mm). Connect the flex pipe to the Retro 

Connector by slipping it into the  4-3/4" (121mm) 

diameter sleeve on the top side of the Con-

nector. Use 3 sheet metal screws to assemble 

these two parts.

6)

  Push  the  flex  pipe  back  up  into  the  ceiling 

support  box,  center  the  Retro  Connector, 

and attach it to the support box, or decorative 

sleeve for double wall solid packed pipe, with 

the sheet metal screws (supplied).  The holes 

in the Retro Connector are pre-punched (refer 

to Diagram 5).

Diagram 4

Diagram 5

7)

  The connection between the appliance and 

the Retro Connector may be completed with 

sections of black direct vent pipe, together 

with an adjustable length.

Diagram 3

Approved for US Installations Only

The use of an existing chimney as an air intake 

is not covered under the ANSI Z21.88a-10007, 

CSA 2.33a-10007 test methods and the resulting 

ITS/WHI product certification. The code Author

-

ity Having Jurisdiction must be consulted prior 

to proceeding with this installation method.

Содержание H35-10

Страница 1: ...AT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier f...

Страница 2: ...has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H35 10 has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...7 7 6 5 1 6 7 3523 57 2 3 7 7 0 127 23 1 2 25 1 3 57 25 6 26 72 7 5 3 57 7 287 285 35 25 5 77 1 216 17 855 17 5 9 6 21 35 9 286 5 9 6 21 3 57 0 7 1 8 5 16 1 5 81 76 1 1 6 0 16 216 72 5 1 6 81 66 27 5...

Страница 4: ...2 25 1 3 57 25 6 26 72 7 5 3 57 7 287 285 35 25 5 77 1 216 17 855 17 5 9 6 21 35 9 286 5 9 6 21 3 57 0 7 1 8 5 16 1 5 81 76 1 1 6 0 16 216 72 5 1 6 81 66 27 5 6 67 7 6 2 127 352 7 21 5 1 02 47 5 9 3...

Страница 5: ...rangements 20 Vertical Termination With Co linear Flex System 23 DV Stove Horizontal Termination Vent Kit 24 Dura Vent Termination Kit 26 Horizontal Installations 27 Rigid Vent system 27 Vertical Term...

Страница 6: ...25 1 NFPA 501A Manufactured Home Installations Standard or ANSI A119 2 ou NFPA 501C Standard for Recreational Vehicles This appliance is only for use with the type of gas indicated on the rating plate...

Страница 7: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 8: ...isapplianceisonlyforusewiththetype of gas indicated on the rating plate This appliance is not convertible for use with othergases unlessacertifiedkitisused BEFORE YOU START Safe installation and opera...

Страница 9: ...h the operation to use the fireplace INSTALLATION CHECKLIST 1 Locate your appliance Refer to the following sections a Clearances to combustibles b Locating Your Gas Stove c For venting requirements se...

Страница 10: ...f unit LOCATING YOUR GAS STOVE When selecting a location for your stove ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and prope...

Страница 11: ...lve cover plate to the base panel through the large grommet 8 Attach the connectors black and red of Fan Grey wire to the IFC connectors black and red NOTE Do remember to follow the wire color code i...

Страница 12: ...ver 3 Remove upper panel 4 Remove all the 4 screws that secure elbow to unit using a 1 4 magnetic nut driver 5 Rotate elbow 180O 6 Secure the elbow with 4 screws 7 Reverse steps 6 1 to reinstall the u...

Страница 13: ...11mm socket 3 Remove top cast grill by pulling it up 5 Loosen front casting mounting bolts using a 7 16 or 11 mm socket 6 Open the valve aceess door and loossen the bottom front casting bolts using th...

Страница 14: ...e flue pipes must not be connected to any other appliance Thegasapplianceandventsystemmustbevented directly to the outside of the building and never be attached to a chimney serving a separate solid f...

Страница 15: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air...

Страница 16: ...ble Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 0...

Страница 17: ...tion 14 46DVA VCH N A N A N A N A TM 4ST14 Snorkel Termination 36 46DVA HC N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit...

Страница 18: ...mp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent Pro are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product...

Страница 19: ...Homes after first sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show allallowablecombinationsofverticalrunswith horizontal terminations Maximum one 90O elb...

Страница 20: ...permitted Venting Arrangements Straight Horizontal Termination The diagrams show all allowable combina tionsofstraighthorizontalterminationusing Rigid Pipe Restrictor position A Only a snorkel or FPI...

Страница 21: ...ith min of 9 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 8 feet t...

Страница 22: ...te min 1 foot between 90o elbows is required Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalvertic...

Страница 23: ...3 76mm co linear aluminium flex running the full length of the chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Perio...

Страница 24: ...if the centerline cannot be met the adjustable sections will have to be cut e Cut the 4 ft section of rigid pipe to length Attach the 45o elbow to the rigid pipe and ensure that the pipe length when c...

Страница 25: ...e desired size Hint leave an extra 12 to 16 of length this will make the final assembly easier to work with 9 Securethe4 dia flexlinertothe4 adaptorwith Mill Pac and 3 of the 8 x 1 2 screws stainless...

Страница 26: ...the unit to the wall It is also important to note the wall thickness The wall thimble is suitable for 2 x 4 or 2 x 6 wall construc tion Select the amount of vertical rise desired for vertical to horiz...

Страница 27: ...adaptor is installed on the unit at the factory Assemble the desired combination of pipe and elbows to the ap pliance adaptor with pipe seams oriented towards the wall or ceiling as much out of view...

Страница 28: ...4inches Securetheconnection between the vent pipe and the vent cap by attaching the two sheet metal strips extend ing from the vent cap assembly into the outer wall of the vent pipe Use the two sheet...

Страница 29: ...ction Failure to do so may result in drafting or performance issues not covered under warranty 4 Assemblethedesiredlengthsofblackpipeand elbows necessary to reach from the appliance adaptor up though...

Страница 30: ...cleanout doors and caps or plugs for cleanout tee fittings and ash dumps shall be secured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off duri...

Страница 31: ...FOR LEAK TESTING CATHEDRAL CEILINGS Round Support RDS Square Support SQS If your home has a cathedral ceiling no attic space betweentheceilingandtheroof installthechimney and support as follows 1 Situ...

Страница 32: ...When finished reading manometer turn off the unit disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but not over tightened Caution Carbon will...

Страница 33: ...t cap to expose the pilot orifice 6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and di...

Страница 34: ...l first by carefully slipping it between the back wall of the firebox and the rear log bracket Back Panel Diagram 1 4 Before installing the side brick panels loosen thescrewsforthebricktabsenoughsotha...

Страница 35: ...02 48 C 02 44 B 02 56 F 02 47 E 02 45 Embers Embers C 02 44 Pins on Rear Log Support A 02 43 B 02 56 4 Place Rear Log A 02 43 on the two pins on the rear log support 5 Place the Middle Left Log B 02...

Страница 36: ...ULC or UL approved may be used CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 10 System Wire Size M...

Страница 37: ...ve the grounding prong from this plug Note 4 AA Batteries must be installed into the back up battery compartment however for this unit to operate when power is lost See battery back up instructions in...

Страница 38: ...X8 X9 X6 11 5 X7 SW1 1 5V AA type 1 5V AA type 1 5V AA type 1 5V AA type RED YELLOW YELLOW BLACK BLACK GREEN VARIABLE LIGHT MAIN LINE SPARK FLAME DETECT RED BLACK BATTERY PACK MAIN ON OFF SWITCH YELLO...

Страница 39: ...hile it is hot OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and en closed to prevent possible shock 3 Check...

Страница 40: ...tely 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on...

Страница 41: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Страница 42: ...and and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFAC...

Страница 43: ...MENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If...

Страница 44: ...t off electrical supply 3 Lift off cast top and place on a soft surface 4 Loosen bolts securing cast front slide light as sembly bracket upward to release 5 Remove two 2 screw to remove bulb housing L...

Страница 45: ...7 Remove the cast front See page 13 for instruc tions 8 Remove the glass front assembly by opening the the 2 latches 9 Carefullyremovethelogs embersandrockwool 10 Remove burner see diagram below Note...

Страница 46: ...743 201 Cast Top Charcoal Grey 743 205 Cast Top Timberline Brown 743 207 Cast Top Seaside Sand 15 743 211 Cast Left Charcoal Grey 743 215 Cast Left Timberline Brown 743 217 Cast Left Seaside Sand 16...

Страница 47: ...rifice LP 911 039 Novasit Pilot Hood 2 way 911 137 Pilot Hood Clip 911 037 Flame Sensor 911 038 Flame Electrode 904 240 Burner Orifice 37 NG 904 390 Burner Orifice 52 LP 904 529 5 32 Allen Key Pilot O...

Страница 48: ...48 Hampton H35 10 Direct Vent Freestanding Gas Stove 48 notes...

Страница 49: ...Hampton H35 10 Direct Vent Freestanding Gas Stove 49 49 notes...

Страница 50: ...50 Hampton H35 10 Direct Vent Freestanding Gas Stove 50 notes...

Страница 51: ...d if requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufactur...

Страница 52: ...staller ____________________________________________________________ Phone ____________________________________________________________ Date Installed _________________________________________________...

Отзывы: