Hampton® H35-10 Direct Vent Freestanding Gas Stove
|
14
installation
INSTALLATION
PRECAUTIONS
These venting systems are engineered products that
have been designed and tested for use with the H35-
NG10, and H35-LP10. The warranty will be voided
and serious fire, health or other safety hazards may
result from any of the following actions:
1)
Installation of any damaged Direct Vent compo-
nent
2)
Unauthorized modification of the Direct Vent
System
3)
Installation of any component part not
approved by FPI - Fireplace Products
International Ltd.
4)
Installation other than as instructed by the ap-
proved rigid pipe manufacturers and FPI Fireplace
Products International Ltd.
Warning: Always maintain required
clearances (air spaces) to nearby com
-
bustibles to prevent a fire hazard. Do
not fill air spaces with insulation.
Be sure to check the vent termination clearance
requirements from decks, windows, soffits, gas
regulators, air supply inlets and public walkways as
specified in the "Exterior Vent Terminal Locations"
section and in your local building codes.
The gas appliance and vent system must be
vented directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas-burning appliance.
Each
direct vent gas appliance must use it's own separate
vent system. Common vent systems are prohibited.
SAFETY PRECAUTIONS FOR
THE INSTALLER
1)
Wear gloves and safety glasses for protection.
2)
Exercise extreme caution when using ladders or
on roof tops.
3)
Be aware of electrical wiring locations in walls
and ceilings.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be vented
directly to the outside of the building, and never
be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
Common vent systems are prohibited.
IMPORTANT
Read all instructions carefully before starting the
installation. Failure to follow these instructions may
create a fire or other safety hazard, and will void the
warranty. Be sure to check the venting and clear-
ance to combustible requirements. Consult your
local building codes before beginning installation.
The location of the termination cap must conform
to the requirements in the "Exterior Vent Terminal
Locations" section.
VENT RESTRICTOR
POSITION
Vent restriction is required for certain venting instal-
lations, see the diagrams in "Venting Arrangement"
section to determine if they are required for your
installation.
To set the Vent restriction as indicated in the dia-
grams in the "Venting Arrangement" section, simply
loosen the screws and push the vent restrictor plate
to the correct position. Tighten the screws.
Horizontal Termination: Position "A"
Vertical Termination: Position "B"
VENTING
INTRODUCTION
The Horizontal Termination Kit and the rigid pipe
venting systems, in combination with the Direct
Vent Freestanding Gas Stoves, H35-NG10 and
H35-LP10, have been tested and listed as direct
vent heater systems by Warnock Hersey.
These units use the "balanced flue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer pipe
draws outside combustion air into the combus-
tion chamber thereby eliminating the need to use
heated room air for combustion and losing warm
room air up the chimney.