Page 28
a. Remove four screws which secure metal cover on control
panel assembly.
b. Replace bulb with No. 12 GE 6.3V .15A miniature 2-pin.
c. To replace power switch, unsolder two black leads from
generator power panel.
d. Compress springs on sides of switch and push through front
of control panel.
3–15 PERCUSSION CIRCUITRY, L–100A
With the exception of power supply and terminal strip assembly,
, the percussion circuitry is mounted on the lower left
end block. If access to end block circuitry is required, remove
control knobs before removing end block from organ.
3–16 SIX-VOICE PERCUSSION CIRCUITRY, L–100–1
The power supply, 127–000007 and pedal control board assembly,
063–042051, are mounted on the left (rear view) wall of the
console.
The rhythm voice board, 124–000114, is located on the bottom left
(rear view) of the console.
Содержание L-100 Series
Страница 1: ......
Страница 6: ......
Страница 9: ...Page 9 Figure 1 4 Block Diagram L 100 Series Figure 1 5 Typical Tone Generator...
Страница 38: ...Page 38 This page intentionally left blank...
Страница 40: ...Page 40 Figure 5 3 Schematic Diagram L 100A Percussion Unit Figure 5 3A Parts Layout L 100A Percussion Unit...
Страница 44: ...Page 44 Figure 5 7 Wiring Diagram L 100 Organ...
Страница 45: ...Page 45 Figure 5 8 Wiring Diagram L100 1 and L 100 2 Organs...
Страница 46: ...Page 46 Figure 5 9 Wiring Diagram L 200 Organ...
Страница 49: ...Page 49 Figure 5 13 Parts Layout AO 41 Vibrato Amplifier...
Страница 50: ...Page 50 Figure 5 14 Parts Layout AO 47 126 000023 Vibrato Amplifier...
Страница 51: ...Page 51 Figure 5 14A Comparison Between AO 41 and AO 47 Vibrato Amplifiers...
Страница 52: ...Page 52 Figure 5 15 Parts Layout AO 42 117 000019 Percussion Amplifier...
Страница 53: ...Page 53 Figure 5 16 Parts Layout AO 43 126 000017 Power Amplifier...
Страница 54: ...Page 54 Figure 5 17 Power Amplifier Fuse Location Canadian 101 000130...