Page 12
The key contacts are connected through resistance wires to the
manual terminal strips. The manual wiring chart,
,
shows how the contacts of each key are connected to the proper
frequencies to supply the fundamental and harmonics of that
particular key. The blank spaces indicate that no key contact is
used, inas much as the higher harmonics of these keys are not
required. Since the percussion control circuit is keyed through the
6th harmonic busbar, the blank spaces in this row have contacts
connected to ground through resistance wires.
The busbars of each manual, each one carrying a certain
harmonic, are wired to the appropriate harmonic drawbars for that
manual through the “Drawbars” tab.
Figure 1–8: Manual Wiring Chart
Содержание L-100 Series
Страница 1: ......
Страница 6: ......
Страница 9: ...Page 9 Figure 1 4 Block Diagram L 100 Series Figure 1 5 Typical Tone Generator...
Страница 38: ...Page 38 This page intentionally left blank...
Страница 40: ...Page 40 Figure 5 3 Schematic Diagram L 100A Percussion Unit Figure 5 3A Parts Layout L 100A Percussion Unit...
Страница 44: ...Page 44 Figure 5 7 Wiring Diagram L 100 Organ...
Страница 45: ...Page 45 Figure 5 8 Wiring Diagram L100 1 and L 100 2 Organs...
Страница 46: ...Page 46 Figure 5 9 Wiring Diagram L 200 Organ...
Страница 49: ...Page 49 Figure 5 13 Parts Layout AO 41 Vibrato Amplifier...
Страница 50: ...Page 50 Figure 5 14 Parts Layout AO 47 126 000023 Vibrato Amplifier...
Страница 51: ...Page 51 Figure 5 14A Comparison Between AO 41 and AO 47 Vibrato Amplifiers...
Страница 52: ...Page 52 Figure 5 15 Parts Layout AO 42 117 000019 Percussion Amplifier...
Страница 53: ...Page 53 Figure 5 16 Parts Layout AO 43 126 000017 Power Amplifier...
Страница 54: ...Page 54 Figure 5 17 Power Amplifier Fuse Location Canadian 101 000130...