63
PART 7. SERVICING
H. STATUS READINGS
(FIGURE 7-4) STATUS READING INSTRUCTIONS
(TABLE 7-5)
TEMPERATURE
(
O
F)
RESISTANCE
(OHM)
TEMPERATURE
(
O
C)
RESISTANCE
(OHM)
32
32550
0
32550
41
25340
5
25340
50
19870
10
19870
59
15700
15
15700
68
12490
20
12490
77
10000
25
10000
86
8059
30
8059
95
6535
35
6535
104
5330
40
5330
113
4372
45
4372
122
3605
50
3605
131
2989
55
2989
140
2490
60
2490
149
2084
65
2084
158
1753
70
1753
167
1481
75
1481
176
1256
80
1256
185
1070
85
1070
194
915
90
915
203
786
95
786
I. APPLIANCE SENSOR RESISTANCE TABLE
Sensor list and other details on screens will vary from system to system
Содержание XL800
Страница 6: ...6 PART 1 GENERAL INFORMATION As a Stand Alone Appliance HOT CONTROL MENU NAVIGATION ...
Страница 7: ...7 PART 1 GENERAL INFORMATION Appliance as Part of a Cascade HOT CONTROL MENU NAVIGATION ...
Страница 19: ...19 PART 2 ELECTRICAL B INTERNAL WIRING CONNECTION continued XL BCB LAYOUT ...
Страница 21: ...21 PART 2 ELECTRICAL XL CASCADE BOX ...
Страница 31: ...31 PART 4 VENTING Direct Vent Terminal Clearances ...
Страница 32: ...32 PART 4 VENTING Direct Vent Terminal Clearances continued Other Than Direct Vent Terminal Clearances ...
Страница 33: ...33 PART 4 VENTING Other Than Direct Vent Terminal Clearances continued ...
Страница 69: ...69 PART 10 PARTS BREAKDOWN 1A 1B PART 10 PARTS BREAKDOWN 2 ...
Страница 70: ...70 PART 10 PARTS BREAKDOWN 3 4 5 6 7 8 9A 9B 9C 10 4 ...