Instruction Manual PSx3xxC
16
Name
Index
number
Function
Range of
value
Back
up
Delivery
State
R/W
delivery state
204F
writing
‘-1’:
generates the delivery state without
modifying the CAN address and the baud
rate (starts initial reference loop, then
positioning to the middle of the
measurement range)
wr
iting ‘-2’:
generates the delivery state (sets CAN
address SDO #2026 to 1, baud rate SDO
#2027 to 500 kBaud, starts initial
reference loop, then positioning to the
middle of the measurement range)
A different CAN address or baud rate is
only active after reset or reset
communication!
writing ‘1’:
saves all parameters in the EEPROM
reading directly after boot:
0
content of memory correct
≠ 0
content of memory incorrect
reading after saving:
0
saving finished successfully
≠ 0
saving is still in progress or is
finished incorrectly (the time for saving is
up to 100 msec)
-1, -2 or
1
16 bit
no
R/W
Содержание PS*3**C series