Name
Index
number
Function
Range of
value
Back
up
Delivery
State
R/W
rpm limit for
aborting run
201A
value in % of the target rpm
30...90
16 bit
yes
30
R/W
time elapsed
until speed
falls below
rpm limit for
aborting run
201B
value in msec
50...500
16 bit
yes
200
R/W
acceleration
201C
value in rpm per sec.
see table
16 bit
yes
see
table
R/W
deceleration
201D
value in rpm per sec.
see table
16 bit
yes
see
table
R/W
length of loop 201F
minimum number of increments which the
drive moves in a pre-defined direction
when approaching a target position
value in increments (value = 0
no loop)
0.025…1
rotations
or 0
32 bit
yes
250
R/W
maximum
rpm, counter-
clockwise
2020
value in rpm
see table
16 bit
yes
see
table
R/W
maximum
rpm,
clockwise
2021
value in rpm
see table
16 bit
yes
see
table
R/W
size of
individual
increment
2022
number of increments when external keys
pressed (or when activating a jog run bit)
for a short-time
1...100
16 bit
yes
1
R/W
idle period for
manual run
2023
Span of time a manual run key must be
pressed (or a jog run bit must be
activated) in order to begin a manual run
value in steps of 5 msec
20...2000
16 bit
yes
200
R/W