Differential locking valve
Possible faults
Possible causes
Diff. locking valve does not switch on
No power at the solenoid (coil: approx. 5.7
Ω
)
Feed pressure too low or not provided
Aperture in connection X is blocked
Series piston jams
O–ring on series piston is defect
Valve switches – pump is pressurised
Consumer is blocked (wheel stands still)
Divider piston jammed
Aperture bore in divider piston blocked