Citytrac 4200
Citymaster 1200
Citycleaner
Service Documents
For internal use only
Status
March 2009
Page
60 of 108
5.4.4 Proportional throttle cartridge
Attention:
When disassembling the throttle cartridge, pay attention
that the threaded flange
is only turned clockwise
to align
the coils.
There must be a gap between the bodies of the coils
and the flange.
Coil resistance: 6.5 Ohm
Threaded flange
Screws
(7 - 9 Nm)
Gap