Citytrac 4200
Citymaster 1200
Citycleaner
Service Documents
For internal use only
Status
March 2009
Page
19 of 108
Bowden cable, engine speed adjustment
Stop screw reverse pedal
wheel speed
100 rpm
Throttle
Idling 1100 rpm
Max. speed 2750
3. Bowden cables in the hydraulic pump:
•
Raise the front of the machine, set the hand throttle to "Transport mode", actuate the parking brake and secure the machine by
positioning chocks against the rear wheels.
•
Disconnect both cables from the accelerator pedal and check that the pedals are parallel.
•
Hook in the cables for the forward ride and adjust them so that the pump is not moved when the pedals are in a neutral position.
Adjust the stop screw so that the average of both front wheel speeds is maximally 225 rpm.
•
Hook in the cable for reverse ride and adjust until the average speed is 100 rpm
Microswitch
S22
here