Citytrac 4200
Citymaster 1200
Citycleaner
Service Documents
For internal use only
Status
March 2009
Page
85 of 108
No jumpers
Operation as Citytrac with mower
•
The hydraulic circuit is only activated after switching on the “mower circuit”.
•
The attachment switches off automatically when the front attachment support is raised.
•
The hydraulic circuit is switched off immediately the driver leaves the seat and must be reactivated
after the seat contact has been closed again by switching it "off and on again".
Jumper, pin 1 to pin 2:
Optional operation as Citymaster or Citytrac
(not for mower operation)
•
The hydraulic circuit is only activated after switching on the “mower circuit”.
•
When the front attachment support is raised, the attachment device runs again (till September 2008).
•
The attachment switches off automatically when the front attachment support is raised (from September 2008).
•
The hydraulic circuit is switched off one second after the driver leaves the seat and must be reactivated
after the seat contact has been closed again by switching it "off and on again".
Can be used for attachment devices which should continue to run after being raised. Is not currently used by Hako.