Citytrac 4200
Citymaster 1200
Citycleaner
Service Documents
For internal use only
Status
March 2009
Page
86 of 108
Jumper, pin 4 to pin 7:
Operation as Citymaster or Citytrac with mulchmower (hydraulic compound circuit) or spreader
•
This enables the continual operation of the proportional hydraulic circuit.
The connector necessary to implement this bridging function belongs to the scope of delivery of the attachment device.
Jumper pin 1 to pin 2; pin 2 to pin 3 and pin 4 to pin 7:
Operation as CM1200
•
The hydraulic circuit is only activated after switching on the “mower circuit“.
•
When the front attachment support is raised, the attachment device runs again (till September 2008).
•
The attachment switches off automatically when the front attachment support is raised (from September 2008).
•
The hydraulic circuit is
not
switched off when the driver leaves the seat.
•
This enables the continual operation of the proportional hydraulic circuit.
There is a connector (cable harness W17) for this jumper which belongs to the functional scope of the brush unit. It is assigned spare
part no.
01161150