10. Error Table With Information
On Service Display
Error code in
Malfunction
Remark
the display
1.2.6.3.
Electronic circuit-breaker Jammed? Lifting element stopped by
Brush lifting element
limit stop before being switched off by
1); 2); 3); 4); 5)
micro-switch? Check coding of
Module 1 Measure operating current
(approx. 3.5A max. during lifting)
1.3.5.1.
Thermal switch
Jammed? Permanent contact to border
Side brush
during ride? Wire broken since NC
1); 2)
activation? Check 35 A fuse; Measure
operating current (approx. 8 A max.)
1.3.6.1.
Blocking protection
Jammed? Permanent contact to border
Side brush
during ride? Wire broken since NC
1); 2)
activation? Check 35 A fuse; Measure
operating current (approx. 8 A max.)