Foil 109
10. Error Table With Information
On Service Display
Error code in
Malfunction
Remark
the display
4.5.3.2.
CAN operator panel
Check CAN bus to Cleaning agent/SWA
Code B no response; operator panel; check contacts and
timeout
connectors; check resistance (120
W
);
(for Cleaning agent /
(60
W
due to parallel connection)
SWA) 1); 5)
Check voltage supply of operator panel
(voltage transformer)
4.6.1.1.
Internal
Check contacts of all connectors on
control unit error
control electronics (for corrosion);
1); 2); 3); 4); 5)
check voltage supply (current transformer)
replace control electronics