Foil 91
10. Error Table With Information
On Service Display
Error code in
Malfunction
Remark
the display
1.2.5.2.
Thermal switch
Wire broken since NC activation?
Brush motor
Measure operating current (approx. 12 A
1); 2); 3); 4); 5)
for a motor when operated without in-
creased pressure and on Fama Famin)
Motor overload due to unfavourable floor-
brush-combination and/or permanent
ride with increased ground pressure?
1.2.5.5.
Thermal switch
Wire broken since NC activation?
3rd Brush motor
Measure operating current (approx. 12 A
(Modul3 Code C)
for a motor when operated without in-
4) ; 5)
creased pressure and on Fama Famin)
Motor overload due to unfavourable floor-
brush-combination and/or permanent
ride with increased ground pressure?