Foil 68
9.2.3 ZAPI Controller
4) EEPROM DATA KO
Data of the memory area controlling the hourmeter counter are corrupted. If alarm disappears after
having switched key switch OFF and ON again, mind that the hourmeter counter is reset to zero then.
5) EEPROM OFF LINE
Error in the non-volatile memory containing those values of the hourmeter counter concerning the
programmable parameters and the saved alarms. If error still persists after having switched key
switch OFF and ON again, replace controller!