Foil 64
9.2 ZAPI Controller
Description of control connections of the ZAPI controller
A1
RV1
Speed reduction 1; active if no positive voltage is applying
A2
IRE
Emergency inversion acc. to Europ. standard; active if a pos. voltage is applying
A3
MT
Tiller micro switch; active if a pos. voltage is applying
A4
NT2
Activation of neg. direction contactor forward ride (auto-stop),
Bypass contactor, general contactor or electric brake (standard)
A5
CH
con (from key switch)
A6
IRZ
Emergency inversion ("ZAPI standard"); active if no positive voltage is applying
A7
RV2
Speed reduction 2; active if no positive voltage is applying
A8
PT
Activation positive for all contactors and micro-switches
A9
MA
Micro-switch forward ride; active if a pos. voltage is applying
A10
MI
Micro-switch reverse ride; active if a pos. voltage is applying
A11
NT1
Activation negative direction contactor reverse ride (auto-stop)
or both direction contactors (standard)
A12
NPOT
Potentiometer negative
A13
CPOT
Potentiometer arm
A14
PPOT
Potentiometer positive (13V; output impedance 82Ohm)