Foil 38
5. Specific Customer
Settings
Entry into programming
1. Switch off machine by key switch
2.
Simultaneously press ”G" and "O" buttons and hold depressed, then switch on
key switch
3. Hold both buttons depressed as long as the software version appears in the
display, then release both buttons
Then the programmed settings for the following points are displayed automatically:
Display of last (remedied) error upon switching ON: yes / no
Water stage at start of cleaning: last selected stage/ always medium stage
Switch on cleaning agent together with switching ON water: yes / no (B 1100 & B1100 PB1230)
Water stage for Scrubbing and suction: last selected stage/ always medium stage
(B1050PB / B1050CB / B1050 PB 1230)
Switch over to SWA upon water ON: clear water / SWA (B 1100 only)
Switch on side brush/side broom together with switching ON scrubbing: yes / no (B1050PB/CB)
Switch on side brush together with switching ON scrubbing: yes / no (B 1100 only)
Filter shaking: in interval / as long as button is depressed (B 1100 & B1100 PB 1230)
Switch on filter suction together with switching ON sweeping: yes / no (B 1100 & B1100 PB 1230)
Automatic filter shaking after sweeping: yes / no (B 1100 & B1100 PB 1230)
Содержание 7580.02
Страница 22: ...Foil 22 3 Machine Type Settings Control electronics A1 X2 B C A B1100 B1050 PB CB B1050PB 1230 B1100 PB 1230...
Страница 113: ...Foil 113 11 Notes...
Страница 114: ...Foil 114 11 Notes...
Страница 115: ...Foil 115 11 Notes...
Страница 116: ...Foil 116 11 Notes...