– 61 –
The Diverter is the key component which allows
lower water use, by alternating water to the:
• Lower spray arm
• Silverware wash
• Mid/upper spray system (bottle wash)
• Mid spray arm and upper spray system) or
lower spray arm reverse (some models)
Operation
The rotation of the pressure diverter is counter-
clockwise as viewed from the top. The control
will seek the lower primary as the start of the
circulation cycle. Lower reverse and silverware
wash are only used during the main wash
segment of a cycle. A short spray will be
detected from the silverware wash, mid and
upper spray systems as well as the lower reverse
until the diverter is positioned to the lower primary
port.
Two Port Diverter Removal
The diverter top may be removed by removing
one 1/4-in. hex-head screw and pressing in on
the locking tab and turning counter clockwise
to remove. Removing the top will expose the
diverter check ball.
Pressure Diverter (Four Port)