Error Codes
(Indoor/Outdoor)
F6/LED1: 12 Flash
Ambient Temperature Sensor Failure
F7/LED1: 11 Flash
Suction Temperature Sensor Failure
F21/LED1: 10 Flash
Defrost Temperature Sensor Failure
F25/LED1: 13 Flash
Discharge Temperature Sensor Failure
●
E1/LED1: No Flash
Room Temperature Sensor Failure
E2/LED1: No Flash
Indoor Coil Temperature Sensor Failure
Complete the “Check This First” Flow
Chart before continuing.
Models:
AW09EH2VHD
AW12EH2VHD
AW18EH2VHD
1U09EH2VHD
1U12EH2VHD
1U18EH2VHD
Yes
Yes
Yes
Yes
No
No
No
No
Go to next step
to test the board
as well before
sensor as well if
previous step.
Re-seat and
Start
wires for the faulting sensor. Does
(See Reverse side.)
solder joints or through the top of the Molex
Is the temperature at the
sensor out of operating
PAGE 40
●
ERROR CODES and Troubleshooting
Содержание AW09EH2VHD
Страница 2: ... This page intentionally left blank ...
Страница 4: ...Failure to follow any CAUTION may in some cases result in grave consequences ...
Страница 6: ...PAGE 6 ...
Страница 9: ...5VDC and 15VDC pulsing communication connection between the PCB and the IPM ...
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ...Connector for coil temperature sensor and room temperature sensor ...
Страница 17: ......
Страница 19: ......
Страница 22: ......
Страница 23: ......
Страница 26: ...PAGE 32 ...
Страница 50: ...Error Code E7 LED1 15 Flash Wiring Diagram Reference PAGE 50 ERROR CODES and Troubleshooting ...