Haier Ductless Technical Support
Phone: 866.814.3633 (option 3) Email: [email protected] Online: www.HaierDuctlessHelp.com
Rev. 04-20
Ductless Troubleshooting
PAGE 56
●
Red
Orange
Yellow
Pink
Blue
Red
296.5Ohm
295.5 Ohm
296.3 Ohm
296.1 Ohm
Orange
594.5 Ohm
595.5 Ohm
594.5 Ohm
Yellow
594.3 Ohm 594.5 Ohm
Pink
594.3 Ohm
Blue
Step 3
Re-seat the plug on the PCB at the conclusion of the test.
Step 2
Refer to the chart shown below for plug pin combinations and
resistance values.
ERROR CODES and Troubleshooting