Page 44
OMNILT SPECIFICATIONS
Size: Controller: 9.1 W x 12.1 H x 3.5 D
Console: 4.6 W x 4.5 H x 1.2 D
Weight: Controller: approx. 4.5 lb.
Console: approx. 0.5 lb.
Operating 32 - 122 degrees F (0 - 50 degrees C)
Ranges: 10 - 95 % relative humidity, non-condensing
Power: 120 VAC, 60 Hz, 60 watts
Transformer: 16.5 VAC, 40 VA, 50/60 Hz
Battery: Sealed Rechargeable Lead–Acid, 12 volts
Bell Fuse: Polyfuse: 1.35A
Device Fuse: Polyfuse: .9 A
Output Fuse: Polyfuse: .3 A
Battery Fuse: Polyfuse: 2.5 A
Polyfuses are permanent fuses that do not need replacement.
Nominal Voltage: 10 - 13.8 VDC
Low Voltage Cut Out: approx. 9 VDC
Typical Current Consumption at Nominal Voltage:
Controller: 105 mA
Console: backlight off, 35 mA
backlight on, 100 mA
CONTROLLER OUTPUTS
UL RATINGS
MAXIMUM
Devices: AUX 12 VDC, CONSOLE, and OUTPUTS 1 and 2:
200 mA
500 mA
Bell: BELL
350 mA
1 A
Outputs: OUTPUTS 1 and 2, each, maximum:
100 mA
100 mA
Backup: Required battery backup hours:
24 hours
Battery: Recommended Battery:
7 Ah
14 Ah
Содержание OmniLT Automation
Страница 1: ...Installation Manual Document Number 21I00 1 Rev A October 2000 ...
Страница 48: ...HAI New Orleans LA U S A ...