FIRE EMERGENCY
This zone type activates the fire alarm for a normally closed (open for alarm) and open collector (short to ground for alarm)
switches. It is not supervised as required for UL Listed Installations and shall NOT be used in such installations.
GAS
This GAS ZONE will generate an alarm, activate the sounder (on - off - on - long off), and make a dial out. This zone type
requires an external 1000-ohm end-of-line resistor.
When Zone 8 is configured as a GAS ZONE, the Zone 8 Jumper (J9) must be
set to the SMK (smoke) position.
AUXILIARY EMERGENCY
This AUXILIARY EMERGENCY ZONE type will generate an alarm (console beeper - no sirens) and make an emergency dial
out when the zone is violated.
TROUBLE
This zone type can be used to monitor the status of an external device, such as the battery status of a wireless security receiver. It
can also used to record events in the event log (i.e. driveway activation, opening of a gate, etc.) without setting off the alarm.
When the zone is open, the zone name will be displayed on the display as "NOT RDY". The alarm is not activated, regardless of
the security mode. The trouble is logged in the event log. The digital communicator (if used) will report the alarm code for the
zone. The voice dialer will not be activated.
FREEZE
This FREEZE ALARM ZONE type will generate an alarm (console beeper, no sirens) and make an emergency dial out.
WATER
This WATER ALARM ZONE type will generate an alarm (console beeper, no sirens) and make an emergency dial out.
FIRE TAMPER
This zone type is used to monitor the wiring to bells and sirens (other than those connected to the Bell Output). The zone will
report trouble if an open, short, or other wiring problem is detected in the supervised bell circuit. This zone will make a digital
dial out when violated. Connect a wire from the Fire Tamper zone to an output configured as a Sounder.
AUXILIARY
A zone defined as AUXILIARY is ignored for security. It is used to activate macros or to conditionalize programs. This is the
default setting for all zones. Zones that are not in use should be configured as AUXILIARY.
KEYSWITCH INPUT
This zone is used to arm AWAY and disarm the OmniLT security system using a toggle (to ground) keyswitch or keypad.
PROGRAMMABLE ENERGY SAVER MODULE
This zone type is for use with the PESM. It converts the Zone and the corresponding Output to operate the PESM. Only Zones 7-
16 can be programmed as PESMs.
OUTDOOR TEMPERATURE
Use this zone type for Outdoor Temperature Sensors.