Connect the remote control, the upper limit switch and the power supply after ensuring that:
-
the supply voltage is 220V50 single phase,
-
The power supply line can support a current of 16A, (starting current = 16A),
-
the power supply line is initially protected by a high sensitivity differential device 30mA for the
protection of persons and a circuit breaker at maximum 16A to protect the winch against
overloads or short circuits,
-
when using an electric extension cable, make sure that the cable conductors have a cross-section
greater than or equal to 2.5mm2 each for a length of 0 to 15m and 4mm2 each for a length of 15 to
30m (maximum length of the electric extension cable: 30m),
-
the device does not work in ATEX zones or explosive atmospheres (presence of flammable gas or
dust etc.), which would require special protection.
Remote control 24V
Plug for
power supply
220V / 2P+T
Upper limit
Plug and
Socket
black 3P+T
for upper limit
switch
Plug and
Socket
grey 4P+T
for remote
control
Содержание 312175001
Страница 14: ...14 SAFETY MARKINGS ON THE MACHINE WINCH BASE LADDER HEADBOARD ACCESSORIES...
Страница 18: ...18 ASSEMBLY EXAMPLES...
Страница 40: ...40 OVERLOAD OF THE DOUBLE TIPPING SKIP MAX PAYLOAD 150kg...
Страница 51: ...51 EXAMPLES OF INCLINED INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Страница 60: ...60 EXAMPLES OF VERTICAL INSTALLATIONS OF THE HOIST ON THE FA ADE OF A BUILDING...
Страница 67: ...67 1 1 2 2 2 1 4 4 3 3...
Страница 70: ...70...
Страница 75: ...75...
Страница 86: ...86 ELECTRICAL DIAGRAM OF THE ABM VF 200 250 WINCHES for MAXIAL EXCELLIUM and EXPERT...