![H3C UniServer R6900 G3 Скачать руководство пользователя страница 191](http://html2.mh-extra.com/html/h3c/uniserver-r6900-g3/uniserver-r6900-g3_user-manual_3183064191.webp)
11-32
Riser card name
Ports on the riser card
Corresponding ports on the system board
Riser card 1
SAS port A1
SAS port A1 on compute module 1
SAS port A2
SAS port A2 on compute module 1
SAS port B1
SAS port A1 on compute module 2
SAS port B2
SAS port A2 on compute module 2
Supercapacitor port 1
Supercapacitor port 1 on compute module 1
Supercapacitor port 2
Supercapacitor port 1 on compute module 2
Riser card 2
N/A
N/A
Riser card 3
SAS port A1
SAS port B1 on compute module 1
SAS port A2
SAS port B2 on compute module 1
SAS port B1
SAS port B1 on compute module 2
SAS port B2
SAS port B2 on compute module 2
Supercapacitor port 1
Supercapacitor port 2 on compute module 1
Supercapacitor port 2
Supercapacitor port 2 on compute module 2
NOTE:
•
For more information about the SAS and supercapacitor ports on a riser card, see "
•
For more information about the SAS and supercapacitor ports on the system board, see "
."
Fan modules
The server must be configured with six hot swappable fan modules, each of which includes two
fans.
shows the layout of the fan modules in the chassis.
The fans support N+1 redundancy.
During system POST and operation, the server will be powered off through HDM if the temperature
detected by any sensor in the server reaches the critical threshold. The server will be powered off
directly if any key components such as processors exceed the upper threshold.