6-22
For the GPU module to take effect, make sure processor 2 of the compute module is in position.
Procedure
The procedure is the same for installing GPU modules GPU-P4-X, GPU-P40-X, GPU-T4, GPU-P100,
GPU-V100, and GPU-V100-32G. This section uses the GPU-P100 as an example.
To install a GPU module in a compute module:
1.
Power off the server. For more information, see "
2.
Remove the security bezel, if any. For more information, see "
3.
Remove the compute module. For more information, see "
."
4.
Remove the compute module access panel. For more information, see "
5.
Remove the high mid air baffle. For more information, see "
Replacing air baffles in a compute
6.
Install the GPU module air baffle to the compute module. For more information, see "
the low mid air baffle or GPU module air baffle to a compute module
7.
If the GPU module is dual-slot wide, attach the support bracket provided with the GPU module
to the GPU module. As shown in
, align screw holes in the support bracket with the
installation holes in the GPU module. Then, use screws to attach the support bracket to the
GPU module.
Figure 6-28 Installing the GPU module support bracket
8.
Install the GPU module and connect the GPU power cord:
a.
Hold and rotate the latch upward to open it. For more information, see "
and a PCIe module in a compute module
."
b.
Connect the riser power end of the power cord (P/N 0404A0UC) to the riser card, as shown
by callout 1 in
.
c.
Insert the GPU module into PCIe slot 1 along the guide rails, as shown by callout 2 in
.
d.
Connect the other end of the power cord to the GPU module and close the latch on the riser
card, as shown by callouts 3 and 4 in
.