![H3C UniServer R6900 G3 Скачать руководство пользователя страница 78](http://html2.mh-extra.com/html/h3c/uniserver-r6900-g3/uniserver-r6900-g3_user-manual_3183064078.webp)
6-44
Figure 6-52 Installing a DIMM
9.
Install the removed air baffles. For more information, see "
Replacing air baffles in a compute
10.
Reconnect the cable between the supercapacitor and the main board.
11.
Install the removed riser card in the compute module. For more information, see "
riser card and a PCIe module in a compute module
."
12.
Install the compute module access panel. For more information, see "
13.
Install the compute module. For more information, see "
."
14.
Install the removed security bezel. For more information, see "
15.
Connect the power cord. For more information, see "
16.
Power on the server. For more information, see "
Verifying the installation
Use one of the following methods to verify that the memory size is correct:
•
Access the GUI or CLI of the server:
{
In the GUI of a windows OS, click the
Start
icon in the bottom left corner, enter
msinfo32
in
the search box, and then click the
msinfo32
item.
{
In the CLI of a Linux OS, execute the
cat /proc/meminfo
command.
•
Log in to HDM. For more information, see HDM online help.
•
Access the BIOS. For more information, see the BIOS user guide for the server.
If the memory size is incorrect, re-install or replace the DIMM.
NOTE:
It is normal that the CLI or GUI of the server OS displays a smaller memory size than the actual size
if the mirror or memory rank sparing memory mode is enabled. In this situation, you can verify the
memory size from HDM.