6-18
•
RAID-LSI-9460-8i(4G).
•
RAID-LSI-9460-16i(4G).
Procedure
The procedure is the same for installing storage controllers of different models. This section uses the
RAID-LSI-9361-8i(1G)-A1-X storage controller as an example.
To install a storage controller:
1.
Power off the server. For more information, see "
2.
Disconnect external cables from the rear riser card if the cables hinder storage controller
installation.
3.
Remove riser card 1. For more information, see "
Replacing a riser card and PCIe module at the
."
4.
(Optional.) Install the flash card of the power fail safeguard module to the storage controller:
IMPORTANT:
Skip this step if no power fail safeguard module is required or the storage controller has a
built-in flash card. For information about storage controllers with a built-in flash card, see
"Storage controllers."
a.
Install the two internal threaded studs supplied with the power fail safeguard module on the
storage controller.
Figure 6-22 Installing the internal threaded studs
b.
Use screws to secure the flash card on the storage controller.