6-24
Installing a GPU module to a rear riser card
Guidelines
You can install GPU modules only to the riser card in riser bay 1 or 3.
To install only one GPU module to a rear riser card, install the GPU module in PCIe slot 2. To install
two GPU modules to a rear riser card, install the GPU modules in PCIe slots 2 and 6.
The procedure is the same for GPU modules GPU-P4-X and GPU-T4. This section uses GPU
module GPU-P4-X as an example.
Procedure
1.
Power off the server. For more information, see "
2.
Disconnect external cables from the riser card, if the cables hinder GPU module installation.
3.
Remove the riser card. For more information, see "
Replacing a riser card and PCIe module at
."
4.
Install the GPU module to the riser card. For more information, see "
PCIe modules at the server rear
."
5.
Install the GPU module air baffle to the riser card. For more information, see "
module air baffle to a rear riser card
."
6.
Install the riser card to the server. For more information, see "
Installing riser cards and PCIe
7.
Connect the power cord. For more information, see "
8.
Power on the server. For more information, see "
Installing Ethernet adapters
Guidelines
You can install an mLOM Ethernet adapter only in the mLOM Ethernet adapter connector on riser
card 1. For more information about the connector location, see "Riser cards." When the mLOM
Ethernet adapter is installed, PCIe slot 4 on riser card 1 becomes unavailable.
To install a PCIe Ethernet adapter that supports NCSI, install it in PCIe slot 3 on riser card 1. If you
install the Ethernet adapter in another slot, NCSI does not take effect.
By default, port 1 on the mLOM Ethernet adapter acts as the HDM shared network port. If only a
PCIe Ethernet adapter exists and the PCIe Ethernet adapter supports NCSI, port 1 on the PCIe
Ethernet adapter acts as the HDM shared network port. You can configure another port on the PCIe
Ethernet adapter as the HDM shared network port from the HDM Web interface. For more
information, see HDM online help.
Installing an mLOM Ethernet adapter
The procedure is the same for all mLOM Ethernet adapters. This section uses the
NIC-GE-4P-360T-L3-M mLOM Ethernet adapter as an example.
Procedure
1.
Power off the server. For more information, see "
2.
Disconnect external cables from riser card 1, if the cables hinder mLOM Ethernet adapter
installation.
3.
Remove riser card 1. For more information, see "
Replacing a riser card and PCIe module at the
."