11-33
Figure 11-11 Fan module layout
Air baffles
Compute module air baffles
Each compute module comes with two bilateral air baffles (a right air baffle and a left air baffle). You
must install a low mid air baffle, high mid air baffle, or GPU module air baffie as required.
lists air baffles available for a compute module and their installation locations and usage
scenarios.
Table 11-13 Compute module air baffles
Name
Picture
Installation location
Usage scenario
High mid air baffle
Above the DIMMs between the
two processors.
No riser card is installed
in the compute module.
Low mid air baffle
Above the DIMMs between the
two processors.
A riser card is installed in
the compute module.
If the riser card carries a
GPU module, install a
GPU air baffle instead of
a low mid air baffle.
Bilateral air baffle
Above the DIMMs at the right
of processor 1, or the DIMMs
at the left of processor 2.
N/A