195
[R2000]
system-failure
Use
system-failure
to configure the exception handling method for the master switch.
Use
undo system-failure
to restore the default.
Syntax
system-failure
{
maintain
|
reboot
}
undo system-failure
Default
The master switch adopt the
reboot
method to handle exceptions.
Views
System view
Default command level
3: Manage level
Parameters
maintain
: Specifies that when the system detects any software abnormality, it maintains the current
situation, and does not take any measure to recover itself.
reboot
: Specifies that when the system detects any software abnormality, it recovers itself through
automatic reboot.
Examples
# Set the exception handling method to
reboot
.
<Sysname> system-view
[Sysname] system-failure reboot
temperature-limit
Use
temperature
-
limit
to set the temperature thresholds for a member switch.
Use
undo
temperature
-
limit
to restore the default.
Syntax
temperature-limit
slot
slot-number
hotspot
sensor-number
lowerlimit warninglimit
[
alarmlimit
]
undo temperature-limit slot
slot-number
hotspot
sensor-number
Default
For the default temperature thresholds, see
Fundamentals Configuration Guide
.
Views
System view
Default command level
2: System level
Parameters
slot
slot-number
: Specifies a member switch by its slot number.