146
Matrix for H3C S5800-32C-PWR
Running Version: version1
Version Compatibility List:
version2 (Compatible)
Table 23
Command output
Field Description
Number of Matrices in Table
Number of product versions contained in the current IRF fabric.
Matrix for xx
Product version of the xx series devices.
Running Version
Current system software image version of the IRF fabric.
Version Compatibility List
List of software version compatibility information.
AA
(Compatible)
The version AA system software image is compatible with the current system
software image.
BB
(Incompatible)
The version BB system software image is incompatible with the current system
software image. You must provide the
force
keyword when you execute the
issu load
command.
CC
(Unknown)
The compatibility between the two versions is unknown.
issu accept
Use
issu accept
to accept the ISSU upgrade and delete the auto-rollback timer.
Syntax
issu accept slot
slot-number
Views
System view
Default command level
2: System level
Parameters
slot
slot-number
: Specifies the ID of an IRF member switch. The ID must be the same as that specified in
the
issu load
command.
Usage guidelines
With this command executed, the system deletes the rollback timer and IRF member switches cannot
automatically roll back to the previous version.
Examples
# Accept the ISSU upgrade for the IRF member switch in slot 1.
<Sysname> system-view
[Sysname] issu accept slot 1
Related commands
•
issu load
•
issu commit