9
Content
Meaning
Example
For example, G01 is the ODF of Row G and
Column 01.
B
—Row number of the terminal
device
In the range of 01 to 99, for example, 01-01.
C
—Column number of the
terminal device
R
—Optical receiving interface
T
—Optical transmitting
interface
N/A
Figure 10 Example of a label on an optical fiber between two devices
•
A01-01-05-05-R
—The local end of the optical fiber is connected to Optical Receiving Interface
05 on Slot 5, Chassis 01 in the rack on Row A, Column 01 in the equipment room.
•
G01-01-01-01-T
—The peer end of the optical fiber is connected to Optical Transmitting
Interface 01 on Slot 01, Chassis 01 in the rack on Row G, Column 01 in the equipment room
Figure 11 Example of a label on an optical fiber between the device and the ODF
•
ODF-G01-01-01-R
—The local end of the optical fiber is connected to the optical receiving
terminal on Row 01, Column 01 of the ODF in Row G Column 01 in the equipment room.
•
A01-01-05-05-R
—The peer end of the optical fiber is connected to Optical Receiving Interface
5 on Slot 05, Chassis 01 in the cabinet on Row A, Column 01 in the equipment room.
Engineering labels for DC power cords
These labels are affixed to DC cables that provide power for racks, and the protection grounding
cables including the –48V, PGND, and BGND cables. The labels for DC power cords are affixed to
one side of the identification plates on cable ties.
Table 4 Information on labels affixed to DC power cords
Content
Meaning
MN(BC)-–48Vn
•
Loaded cabinet side
—Only MN is used to identify the cabinet number
(row number and column number in the equipment room).
•
Power cabinet side
—MN identifies the row and column number of the
power distribution equipment like the control cabinet and distribution
MN(BC)-RTN
MN(BC)-PGND
TO:
G0
2
01
01
A 0 1
0 1
0 5
0 5
R
01
T
TO:
A0
1
01
05
O D F
G 0 1
0 1
0 1
R
05
R
Содержание CR16000-F
Страница 13: ...7 Figure 4 Airflow through the CR16005E F chassis Figure 5 Airflow through the CR16010E F chassis...
Страница 40: ...9 Figure 11 Securing the power cord method one Figure 12 Securing the power cord method two...
Страница 47: ...16 Figure 22 Installing an SMB coaxial clock cable...
Страница 66: ...5 Figure 5 Removing a common card Figure 6 Removing a card with a locking clip 1 3 2...
Страница 76: ...15 Figure 19 Replacing an SMB coaxial clock cable...
Страница 89: ...12 Figure 14 Example of a device label...
Страница 96: ...6 Figure 7 Routing DC power cords...
Страница 105: ...8 Figure 8 Repackaging the chassis CR16006 F 1 Accessories box 2 Cardboard box 3 Foam cushion 4 Paper angle bead 2 3 4 1...