Soft Serve Model CS600
13 Troubleshooting Tables
- continued
PROBLEM
PROBABLE CAUSE
REMEDY
184596 25
Dispensed
product too soft.
(Product
temperature
above 19°F
[-7°C])
1.
Dirty air filter.
1.
Clean air filter
2.
Dirty or blocked condenser, restricted
air flow.
2.
Unblock condenser or have cleaned by
your Electro Freeze distributor.
3.
Torque control not set firm enough.
3.
Contact your Electro Freeze distributor
for service.
4.
Component failure.
4.
Contact your Electro Freeze distributor
for service.
5.
Leak in refrigeration system resulting in
little or no refrigeration.
5.
Contact your Electro Freeze distributor
for service.
Compressor and
beater motor
operates only
when
dispensing.
1.
Cylinder thermostat setting too warm or
thermostat defective.
1.
Contact your Electro Freeze distributor
for service.
Compressor and
beater motor do
not operate
when
dispensing.
1.
Plunger switch(es) defective or out of
adjustment.
1. Contact your Electro Freeze distributor
for service.
2.
Time delay defective.
2. Contact your Electro Freeze distributor
for service.
3.
Defective torque control.
3. Contact your Electro Freeze distributor
for service.
Freezer runs
continually and
product gets too
cold.
1.
Plunger not fully closed.
1.
Close plunger completely.
2.
Torque control not set properly or
faulty.
2.
Contact your Electro Freeze distributor
for service.
3.
Starter or relay control points stuck.
3.
Contact your Electro Freeze distributor
for service.
6.
Suction pressure too low.
6.
Contact your Electro Freeze distributor
for service.