ELECTRO FREEZE Model CS600
2
184596
CAUTION
All materials and connec-
tions must conform to
local requirements and be
in compliance with the
National Electric Code
(NEC).
CAUTION
To prevent accidental
electrical shock, a
receptacle with a positive
earth ground is required.
1. Always verify electrical specifi-
cations on the data plate (figure 4-1) of
each individual freezer. Data plate
specifications will always supersede
the information in this manual.
2. This freezer
requires a protected
20 amp 208/230 volt
circuit. Connect the
freezer to a circuit
separate from any
other electrical
equipment. The
power cord on this
freezer connects to a
NEMA 5-20R recep-
tacle. See Figure 3-
1.
3. Supply
voltage must be
within ±10% of
voltage indicated on
the nameplate.
3 Electrical Requirements
4.1
Particulars
4 Specifications
Width
(in/cm)
18-3/8 / 46.7
Height
(in/cm)
35-13/64 / 89.4
Depth
(in/cm)
28-3/32 / 71.4
Weight
(lbs/kg)
240/109
Voltage*
208-230/60/1
Min.Circuit Ampacit
y
20.0
Compressor
1-1/2 HP/6500(BTUH)
1.1kw (Motor)
1.9 kw (Cooling)
Beater Motor
1-1/2 HP / 1.1kw
Refrigerant
R-404a
Charge
20-34 oz/.57-.96kg
Cooling
Water / Air
Hopper
22 qts/21.2 liters
Cylinder
3.7 qts/3.5 liters
*Contact factory for other voltages.
Figure 3-1