ELECTRO FREEZE Model CS600
18
184596
10.2 Draining Product from Freezer
Note:
It is your responsibility to be aware
of, and conform to, the requirements for
meeting local, state, and federal laws
concerning the frequency of cleaning and
sanitizing the freezer.
To remove frozen product from the cylinders,
perform the following steps:
1. Remove the mix feed tube from the
hopper. (See figure 9-3).
2. Place the selector switch in the
"CLEAN" position. Let the beater run for 5
minutes. This will allow the product in the
cylinder to soften.
3. Place a clean, sanitized container
under the dispensing nozzle.
4. Dispense the product until the mix
hopper is empty. Place the selector switch
in the “OFF” position and continue dispens-
ing product until it quits flowing and close
the plunger. If local health codes permit,
cover the rerun product container and place
it in the cooler. (See Section 11, SOFT
SERVE INFORMATION)
5. Pour two gallons (7,6 liters) of cold
water into the hopper. Place the selector
switch to the “CLEAN” position and dis-
pense the cold water. Brush residue from
hopper walls.
Important:
Do not use hot water. Damage to the
freezer could occur.
6. Follow with 2 gallons (7,6 liters) of
warm water and repeat until the freezer
dispenses clear water. With most of the
water dispensed, place selector switch in
the "OFF" position and drain off remaining
water.
7. Prepare 2 gallons (7,6 liters) of
sanitizing solution. Sanitizing solution must
be mixed according to manufacturer’s
instructions to yield 100 PPM available
chlorine solution (example: Stera-Sheen
Green Label). Use warm water (100-110°F or
37-43°C) to wash, rinse, and sanitize.
Figure 10-3
8. Pour sanitizing solution into the
hopper pan. Using a clean brush, scrub the
hopper walls, mix level sensor and the mix
feed port from the hopper to the cylinder,.
Important:
Do not use the “AUTO” position with
sanitizer in the cylinder. The freezer will
be damaged.
9. When the cylinder has filled with
sanitizing solution, place the selector switch
in the “CLEAN” position and allow the beater
to run for 5 minutes. During this time period,
check for leaks around the head, plunger
and drain tube.
10. Place an empty container under
the dispensing head. Drain the sanitizing
solution from the cylinder by slowly pulling
down on the dispense handle. Open and
close the handle several times while drain-
ing.
11. With most of the sanitizing solution
drained, place the selector switch in the
"OFF" position and drain remaining solution
from the freezer and close the plunger.
12. Proceed to disassembly, cleaning
and sanitizing instructions.
Tube-Mix
Feed
O-Ring
O-Ring
Insert-Assy.
Mix Feed