12
SMARTFEED M-4
EN
Marking of the input/output terminal block (top view):
Schematic diagram of the terminal block :
1
10
1.1
1.2
1.3
1.4
1
2
3
4
5
6
7
8
9
24V
DO1
DO2
DO3
DO4
DI1
DI2
DI3
DI4
MASS
10
The outputs are to be connected between terminals 1 to 5 and are arranged as follows:
- Terminal 1: 24 VDC power supply common to the outputs
- Terminal 2: Output No. 1
- Terminal 3: Output No. 2
- Terminal 4: Output No. 3
- Terminal 5: Output No. 4
The inputs need to be connected to terminals 6 to 10 and are arranged as follows:
- Terminal 6: 24VDC Input No. 1
- Terminal 7: 24VDC Input No. 2
- Terminal 8: 24VDC Input No. 3
- Terminal 9: 24VDC Input No. 4
- Terminal 10: Ground 0 VDC common to the inputs
It is recommended to make the connection between the control module and the terminal block using a shielded cable.
The maximum wire cross-section will be 28-16AWG - 1.5mm².
Summary and technical characteristics of inputs and outputs:
Output
Input
Insulation type
Dry contact 24V DC
1 - 24VDC
2-5 - DO1 – DO4 (NO)
Insulated 500 VDC Photocoupler
6-9 - DI1 – DI4 (NO)
10 - Ground (0V)
ON Voltage Vmin/Vmax
+20V to +30 V
15VDC – 28VDC
OFF Voltage Vmin/Vmax
0VDC – 5 VDC
Impedance input
800 KOhm
Rated current at +24 V
Max 2A
10 mA
RISK OF INJURY FROM MOVING COMPONENTS
The reels are equipped with moving components that can catch hands, hair, clothing or tools and cause injuries!
• Do not reach for rotating or moving components or drive parts!
• Make sure that all panels remain closed when in use!
• Do not wear gloves when setting up the wire and changing the wire reel.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
- une note explicative de la panne.