SECTION 4 GENERAL INFORMATION
Gyrus ACMI PlasmaKinetic SuperPulse Generator
USER MANUAL
Part Number: 144012-MB
Page 4-7
“OUTPUT SHORTED, RE-APPLY PEDAL” symbol (Fig 4.10 Screen for shorting of a non-
grasping electrode), until the pedal is released and pressed again. Power levels will remain
the same as those previously in use. This method of resolution is appropriate where the
cause of the short is accidental, transitory and understood.
Fig 4.8 Screen for shorting of a non-grasping electrode
Storage at low temperatures –
The generator will detect where the enclosure temperature
is below the specified minimum allowable for use, and will display a ‘WARMING UP”
message until an acceptable temperature is reached internally, whereupon normal
operation will resume. This condition is possible where the generator has been brought
directly into the operating room from a cold storage environment.
Fig 4.9 Screen for an excessively cold condition
Foot pedals stuck on –
The generator will detect where one or more the foot pedals
appears to be stuck on, and will wait until the condition disappears before resuming normal
behaviour. This condition can be inadvertently caused by the inverting the footswitch or
standing on a pedal as the generator is switched on.
WARMING