REMOTE
CONTROL
97
conf:curr:dc
Sets measurement to DC Current and specifies range.
Parameter: NR2, min, max
Example: conf:curr:dc_10e-3 (DCI, 10mA range)
Example: conf:curr:dc_min (DCI, minimum range)
conf:curr:ac
Sets measurement to AC Current and specifies range.
Parameter: NR2, min, max
Example: conf:curr:ac_10e-2 (ACI, 100mA range)
Example: conf:curr:ac_min (ACI, minimum range)
conf:curr:dcac
Sets measurement to DC+AC Current and specifies range.
Parameter: NR2, min, max
Example: conf:curr:dcac_10 (DC+ACI, 10A range)
Example: conf:curr:dcac_min (DC+ACI, minimum range)
conf:res
Sets measurement to 2W Resistance and specifies range.
Parameter: NR2, min, max
Example: conf:res_10e3 (2W R, 10K range)
Example: conf:res_min (2W R, minimum range)
conf:fres
Sets measurement to 4W Resistance and specifies range.
Parameter: NR2, min, max
Example: conf:fres_10e3 (4W R, 10K range)
Example: conf:res_min (4W R, minimum range)
conf:freq
Sets measurement to Frequency and specifies range.
conf:per
Sets measurement to Period and specifies range.
conf:cont
Sets measurement to Continuity.
conf:diod
Sets measurement to Diode.
conf:temp
Sets measurement to Temperature.
SENSe command
sens:det:rate
Sets detection rate.
Parameter: s (slow), m (medium), f (fast)
Example: sens:det:rate_s (set detection rate to Slow)
sens:det:rate?
Returns detection rate.
Parameter: s (slow), m (medium), f (fast)
sens:temp:tco:type Sets thermocouple type.
Parameter: j (type J), k (type K), t (type T)
Example: sens:temp:tco:type_j (set thermocouple type to J)
sens:temp:tco:type? Returns thermocouple type.
Parameter: j (type J), k (type K), t (type T)
sens:temp:rjun:sim Set
temperature simulation value.
Parameter: NR2
Example: sens:temp:rjun:sim_23
GDM-8200 Series User Manual
98
sens:temp:rjun:sim? Returns
temperature simulation value.
sens:aver:tcon
Selects digital filter type.
Parameter: mov (moving), rep (repeating)
Example: sens:aver:tcon_mov (moving digital filter)
sens:aver:tcon?
Returns digital filter type.
Parameter: mov (moving), rep (repeating)
sens:aver:coun
Sets digital filter count.
Parameter: 2 ~ 127
Example: sens:aver:coun_100 (filter count 100)
sens:aver:coun?
Returns current digital filter count.
Parameter: 2 ~ 127
sens:aver:stat
Turns digital filter On/Off.
Parameter: Boolean
Example: sens:aver:stat_1 (digital filter On)
sens:aver:stat? Returns
digital
filter status, On or Off.
Parameter: Boolean
UNIT command
unit:temp
Selects temperature unit, celsius or fahrenheit.
Parameter: c (celsius), f (fahrenheit)
Example: unit:temp_c (temperature unit celsius)
unit:temp?
Returns temperature unit, celsius or fahrenheit.
Parameter: c (celsius), f (fahrenheit)
CALCulate command
calc:func
Activates advanced measurement functions.
Parameter: rel (relative), max (Max), hold (Hold), db (dB),
dbm (dBm), math (Math), comp (Compare)
Example: calc:func_math (activate math function)
calc:func?
Returns current advanced measurement functions.
Parameter: rel (relative), max (Max), hold (Hold), db (dB),
dbm (dBm), math (Math), comp (Compare)
calc:stat
Turns math function On/Off.
Parameter: Boolean
Example: calc:stat_1 (math function On)
calc:stat?
Returns math function status, On or Off.
Parameter: Boolean
calc:aver:min?
Returns minimum value stored.
calc:aver:max? Returns
maximum
value
stored.